CT technique eliminates the need for X-rays in trauma patients with possible spinal fractures
When trauma patients receive a computed tomography (CT) scan of the chest, abdomen, and pelvis, a technique called CT spine reformatting eliminates the need for X-rays of the thoracic and/or lumbar spine to detect spinal fractures. This technique can lower cost and overall patient radiation exposure, according to a study to be presented at the ARRS 2010 Annual Meeting in San Diego, CA. CT spine reformatting is performed by a CT technician after a CT scan is complete. It helps the radiologist assess the thoracic and/or lumbar regions of the spine without additional imaging, which can reduce cost and patient radiation exposure.
"Background research shows that CT is much more sensitive and specific than X-rays in detecting thoracic and lumbar spine fractures," said Viesha Ciura, MD, lead author of the study. Our study looked at the percentage of trauma patients who had both reformatted CT data and X-rays of the thoracic and/or lumbar region of the spine and the additional radiation dose and cost associated with the unnecessary X-rays," said Ciura.
The study, performed at the University of Calgary, Foothills Medical Centre, included 897 trauma CT scans with spine reformats. 19 percent of the patients with reformatted CT data showing the spine also had X-rays of the same segment of the spine. "In patients with spinal fractures detected on the CT spine reformats, the X-rays provided no additional information, and in fact, some of these fractures were not seen on the X-rays," said Ciura. "Our calculations suggest that in every 1,000 trauma patients, the added radiation dose from spine X-rays that may not have been needed is 170 mSv; the additional cost per 1,000 trauma patients was $19,678.93," she said.
"At a time where radiation issues are gaining increasing importance in considering the utilization of diagnostic imaging, the addition of what appear to be unnecessary X-rays as part of managing trauma needs to be reconsidered," said Ciura.
"At our institution, we have introduced a new protocol, that all trauma patients undergoing CT of the chest, abdomen, and pelvis also have CT reformats of the thoracic and lumbar spine to decrease the costs and excess radiation exposure associated with additional imaging," she said.
Source: American College of Radiology / American Roentgen Ray Society
Related
- Surgical technique relieves painful spine fractures in patients with metastatic cancerSat, 9 Oct 2010, 3:32:39 EDT
- IOF campaign puts spotlight on vastly under-diagnosed and under-treated spinal fracturesTue, 12 Oct 2010, 6:31:07 EDT
- Wrist fracture patients less likely to be evaluated for osteoporosisThu, 1 Oct 2009, 10:24:35 EDT
- Techniques appear to lower radiation exposure from cardiac scans without impairing image qualityWed, 10 Jun 2009, 1:51:20 EDT
- Iterative reconstruction technique significantly reduces patient radiation dose during CT scansWed, 19 Aug 2009, 7:22:19 EDT
Articles on the same topic
- Unlike CT, standard X-rays don't detect the majority of pelvic injuries, study suggestsFri, 7 May 2010, 9:04:54 EDT
- Simple reduction technique decreases radiation dose associated with CT scans of the headThu, 6 May 2010, 8:46:30 EDT
- Image filters improve image quality and lower patient radiation dose associated with CT scansMon, 3 May 2010, 16:32:18 EDT
- Estimated radiation risks associated with abdominal CT scans are greater in younger patientsMon, 3 May 2010, 16:31:52 EDT
- Researchers develop computer-based system to automatically track radiation dose exposure from CT scansMon, 3 May 2010, 16:31:09 EDT
Other sources
- Simple reduction technique decreases radiation dose associated with CT scans of the headfrom Science CentricFri, 7 May 2010, 9:10:31 EDT
- Simple reduction technique decreases radiation dose associated with CT scans of the headfrom PhysorgThu, 6 May 2010, 16:01:03 EDT
- Simple reduction technique decreases radiation dose associated with CT scans of the headfrom Science DailyThu, 6 May 2010, 9:42:33 EDT
- Image filters improve image quality and lower patient radiation dose associated with CT scansfrom Science CentricTue, 4 May 2010, 11:50:53 EDT
- Estimated radiation risks associated with abdominal CT scans are greater in younger patientsfrom Science CentricTue, 4 May 2010, 11:50:52 EDT
- Researchers develop computer-based system to track radiation dose exposure from CT scansfrom Science CentricTue, 4 May 2010, 11:50:31 EDT
- Researchers develop computer-based system to automatically track radiation dose exposure from CT scansfrom PhysorgMon, 3 May 2010, 22:40:23 EDT
- Image filters improve image quality and lower patient radiation dose associated with CT scansfrom PhysorgMon, 3 May 2010, 18:11:49 EDT
- Estimated radiation risks associated with abdominal CT scans are greater in younger patientsfrom PhysorgMon, 3 May 2010, 16:11:48 EDT
Latest Science Newsletter
Get the latest and most popular science news articles of the week in your Inbox! It's free!Learn more about
Check out our next project, Biology.Net
Popular science news articles
- King Richard III found in 'untidy lozenge-shaped grave'
- Detection of the cosmic gamma ray horizon: Measures all the light in the universe since the Big Bang
- UEA scientists make breast cancer advance that turns previous thinking on its head
- Facial-recognition technology proves its mettle
- Cradle turns smartphone into handheld biosensor