12-month ATLANTA trial data show sustained benefit of Catania Stent
Clinical investigators at today's "Innovative Devices and Futuristic Therapies" session during the 20th annual Transcatheter Cardiovascular Therapeutics (TCT) scientific symposium, sponsored by the Cardiovascular Research Foundation, presented 12-month follow-up data from the ATLANTA Trial. The results include zero percent thrombosis in patients discontinuing dual anti-platelet therapy after only 30 days. The ATLANTA Trial is a first-in-man (FIM), prospective, single center, non-randomized, single-arm study involving 55 patients (76 lesions) treated with the CATANIA™ Coronary Stent System with NanoThin Polyzene®-F surface modification for symptomatic ischemic heart disease due to de novo, obstructive lesions of native coronary arteries. The trial was sponsored by CeloNova BioSciences, Inc., maker of the CATANIA™ stent.
At 12 months, in an unusually complex FIM patient population, the results showed zero (0.0) percent stent thrombosis (Academic Research Consortium, or ARC-defined), death, myocardial infarction, stroke, or coronary artery bypass graft. Target lesion revascularization was 10.9 percent (only 3.6 percent clinically driven, 7.3 percent non-clinically driven), with a binary restenosis rate of 6.8 percent (five of 74 lesions analyzed at twelve months). Of note, all patients stopped dual anti-platelet therapy after 30 days, but continued aspirin (100 mg/d) throughout the 12-month period.
The acute angiographic and procedural success rate in the ATLANTA Trial was 100 percent. Independent core laboratories analyzed quantitative coronary angiography and intravascular ultrasound (IVUS) data for all patients immediately after stent implantation and at 6-month follow-up. Further analysis of 1,904 cross sections (19,028 struts) by investigators using Optimal Coherence Tomography at baseline and again at 6-month follow-up in a subset of 15 randomly selected patients revealed complete endothelialization and 99.5 percent stent strut coverage.
"Every clinician is aware of the questions and issues surrounding drug-eluting stents and the increased risk of late and very late stent thrombosis, malapposition, inflammatory or hypersensitivity reactions, as well as the economic impact of maintaining long-term dual antiplatelet therapy," said Corrado Tamburino, MD, PhD, FESC, FSCAI, FSICI-GISE, Professor of Cardiology and Chief of the Cardiovascular Department, Ferrarotto Hospital, Catania, Italy, and lead investigator in the ATLANTA Trial. "The 12-month ATLANTA data indicate that the CATANIA™ stent with Polyzene®-F is truly a new and promising class of stent. Further, the CATANIA™ stent may offer an improved safety profile as evidenced by the fact that there were no deaths, myocardial infarctions, or stent thrombosis in a significantly complex patient population. Economically, this stent has merit, because it does away with the costs associated with long-term dual antiplatelet therapy."
The rapid-exchange, cobalt-chromium CATANIA™ stent carries a CE Mark and is currently available for sale outside of the United States in 60 sizes, in lengths from 8-38mm and in diameters from 2.0-4.0mm. "The CATANIA™ stent represents the next evolution in angioplasty treatment," said Thomas A. Gordy, President and Chief Executive Officer, CeloNova Biosciences, Inc. "Physicians, health care systems, and insurance programs need breakthroughs, not devices that are marginally better than what already exists. Marginal improvements advance competition; we need to be advancing medicine first."
The CATANIA™ stent surface has a thin (35-40 nanometers) surface treatment of highly lubricious Polyzene®-F, a synthesized, inorganic, biocompatible polymer that is anti-thrombotic, anti-inflammatory, bacterial-resistant, and essentially cloaks the device's presence from the body to promote healthy endothelial cell growth without stimulating platelet activation.
"We found the CATANIA™ stent to be highly deliverable, trackable, and flexible in even the most tortuous anatomy," said Dr. Tamburino. "The Polyzene®-F surface treatment endows the stent with exceptional qualities that not only create a highly lubricious system that inspires user confidence and improved pushability, but also hides the stent from the body's defenses, which reduces platelet aggregation and the potential for thrombosis."
Source: The Storch Murphy Group
Related
- Triple antiplatelet therapy appears superior to dual antiplatelet therapySun, 12 Oct 2008, 12:56:38 EDT
- Cogent trial shows lack of adverse interaction between clopidogrel and stomach medicineThu, 24 Sep 2009, 17:59:07 EDT
- Drug-eluting stents better than bare-metal stents for heart attack patientsFri, 25 Sep 2009, 15:35:45 EDT
- Researchers find drug-eluting stents safe, effective for PCI in diabeticsMon, 21 Sep 2009, 14:57:34 EDT
- New devices used to reduce arterial occlusions, provide cardiac support, highlighted at TCT 2008Sun, 12 Oct 2008, 12:56:43 EDT
Articles on the same topic
- Study shows safety and efficacy of blood flow reversal system used during carotid stentingThu, 16 Oct 2008, 16:22:27 EDT
- Study reveals embolic neuroprotection system reduces risk of cardiac eventsThu, 16 Oct 2008, 16:22:24 EDT
- Drug-eluting stents more effective, equally as safe as bare metal stents in clinical trialWed, 15 Oct 2008, 12:22:35 EDT
- New data examine stents and bypass surgery in patients with 3VD and LMDWed, 15 Oct 2008, 7:21:26 EDT
- Late-breaking results of clinical trial on therapeutic endovascular cooling reported at TCT 2008Wed, 15 Oct 2008, 7:21:24 EDT
Other sources
- Study reveals embolic neuroprotection system reduces risk of cardiac eventsfrom PhysorgThu, 16 Oct 2008, 17:07:50 EDT
- Drug-eluting Stents More Effective, Equally As Safe As Bare Metal Stents, Clinical Trial Suggestsfrom Science DailyWed, 15 Oct 2008, 13:36:30 EDT
- New data examine stents and bypass surgery in patients with 3VD and LMDfrom PhysorgWed, 15 Oct 2008, 7:21:10 EDT
Latest Science Newsletter
Get the latest and most popular science news articles of the week in your Inbox!Learn more about
Popular science news articles
- Transcendental Meditation helped heart disease patients lower cardiac disease risks by 50 percent
- Nanoparticles used in common household items caused genetic damage in mice
- Boehringer Ingelheim announces Phase III data of flibanserin in pre-menopausal women with HSDD
- Heart disease found in Egyptian mummies
- Beyond sunlight: Explorers census 17,650 ocean species between edge of darkness and black abyss
- Nanoparticles used in common household items caused genetic damage in mice
- Treatment with folic acid, vitamin B12 associated with increased risk of cancer, death
- Therapy 32 times more cost effective at increasing happiness than money
- 5 exercises can reduce neck, shoulder pain of women office workers
- Transcendental Meditation helped heart disease patients lower cardiac disease risks by 50 percent